Allen-Bradley / Rockwell · PLC CPU · PLC-5/60 processor
Allen-Bradley / Rockwell 1785-L60B
Analysis reviewed: September 11, 2026
What should replace this part?
The documented replacement is ControlLogix 1756 platform (5580 preferred). This is a platform migration, not a drop-in swap.
Move the PLC-5/60 to ControlLogix with conversion tooling — remanufactured units cover the changeover
- Rockwell's end-of-life letter retires the PLC-5 processor family as of June 2017.
- Rockwell's migration program points at 5580 controllers, with tooling that carries RSLogix 5 code forward for validation.
- Remanufactured units and repair services keep the line running while you plan the move.
Your options
What will need to change?
| Hardware | The PLC-5 chassis gives way to a ControlLogix chassis. |
|---|---|
| Software | Move the program from RSLogix 5 to Studio 5000 Logix Designer with the conversion tools. Scan and memory behavior change, so retest the application. |
| Wiring | Existing field wiring carries over through 1492 conversion hardware. Confirm the terminal layout when ordering the adapters. |
| Communications | DH+, RIO, and ControlNet networks move to EtherNet/IP. Re-address devices and rework the network cabling. |
For anything not listed here, check the replacement manual against your existing configuration.
Need help confirming this replacement?
Send us the part number and current setup for 1785-L60B. We'll help determine whether you need a replacement, repair, original-stock sourcing, or a migration.
Request a replacement reviewCan I still buy the original?
Lifecycle
Technical evidence
The recommendation above is based on the sources listed here. OEM source means the manufacturer published it; third-party source means a distributor, repair company or reseller states it. Confidence reflects how directly those sources support the recommendation: High — directly supported by manufacturer documentation. Medium — supported by family-level, secondary, or otherwise less-direct evidence. Low — limited or indirect evidence; verify independently before ordering.
OEM / manufacturer sources
Source excerpt“End of Life for remaining PLC-5 processors; migrate to ControlLogix platform”
Source excerpt“PLC-5 discontinued; migrate to ControlLogix; OEM remanufacturing extends life of PLC-5”
Limitation: Direction comes from Rockwell's migration program, not a per-CPU catalog. There is no single L60B catalog to order — the ControlLogix system needs sizing for your application.
Related replacement analyses
- Allen-Bradley / Rockwell 1747-L553 — Related SLC 500 controller.
- Allen-Bradley / Rockwell 1785-L80B — Related PLC-5 controller.
- Allen-Bradley / Rockwell 1771-IBD — Related PLC-5 I/O module.
- Allen-Bradley / Rockwell 1747-L552 — Related SLC 500 controller.
- Allen-Bradley / Rockwell 1785-L40B — Related PLC-5 controller.
- Allen-Bradley / Rockwell 1756-L61 — Migration destination: ControlLogix platform.